Confocal Microscopy

The Confocal Microscope Core Facility administered by the Department of Neuroscience, Munroe-Meyer Institute at UNMC.

This core provides state of the art digital imaging optical microscopes, quantitative software applications, and expert technical assistance. The resources available at the facility include a Nikon Swept Field advanced laser-scanning confocal microscope (LSCM), a Cascade 512B high quantum efficiency digital camera, Quadview system for Fluorescent Resonance Energy Transfer (FRET) imaging, a fully motorized inverted wide-field imaging microscope (Nikon TE-2000U) for quantitative live-cell and multidimensional imaging, Eppendorf microinjection system, and two computer stations for on and off-line image processing and analysis.

Fluorescence microscopy is an advanced technique widely used in biomedical research. Though highly useful for most applications, the technique experiences serious limitations, notably fuzzy images and phototoxicity. The fuzziness arises from interference, such as diffraction and spherical aberration, and phototoxicity partly derived from the formation of oxygen radicals due to non-radiative energy transfer. A high numerical aperture objective lens provides an in-focus image of a thin plane within the specimen. However, the information from this optical section is often obscured by out of focus interference from fluorescent structures above and below the plane of focus. Confocal imaging and digital deconvolution are two techniques that have been developed to correct this problem.

Although both confocal imaging and computer deconvolution can be effective in virtually eliminating out-of-focus interference, they do nothing to improve phototoxicity. When a fluorophore is excited, there is a probability that instead of decaying to a singlet state and emitting a fluorescence photon, a very reactive triplet state can occur. These relatively long-lived states can damage living cells and bleach the fluorophore in part by the generation of highly reactive singlet oxygens. This problem can be cleared somewhat by soaking fixed specimens in antioxidants (so-called antifade reagents). However, this approach is not applicable for living samples and both photobleaching and phototoxicity can be very extensive for long-term imaging. Our high-speed multiple pinhole/slit scanning system configuration with an ultra quantum efficiency CCD camera enables us to perform long-term fluorescent live imaging with minimum photobleaching.

Equipment

Nikon Swept Field Confocal Microscope

  • With multiple slit/pinhole modes for fast scanning with Cascade 512B CCD camera
  • X-Y-Z motorized Nikon TE2000-U Inverted microscope for automated multiple position imaging
  • Widefield Fluorescence connected with a xenon lamp and QuadView FRET module and CoolSnap HQ CCD camera
  • Environmental Chamber for long-term live imaging
Nikon swept field
Argon and Argon/Krypton lasers with 488, 514, 568, and 647nm wavelengths connected to the sweptfield scanner head for confocal imaging. Argon and Argon/Krypton lasers
Xenon lamp (1000 hr lifetime and better stability compared to Hg lamp)
Epi-fluorescence with up to 10 excitation filters (FITC, Dapi, Texas Red, Cy5, CFP, and YFP)
Connected to the Quad View FRET module for up to 4 color FRET imaging
Calcium Imaging with MetaFluor ratiometric software package
Xenon Lamp
Quad View FRET module for up to 4 color FRET (Fluorescence Resonance Energy Transfer) imaging.
Available filters: CFP/YFP; FITC/Texas Red non-FRET
Quad View Fret module

Image Processing Software 

  • MetaMorph for microscope operation and image processing
  • MetaFluor ratiometric package for calcium imaging
  • New NIS Elements Software (Nikon)
  • AutoQuant 2/4 D AutoDeblur AutoVisualize for confocal and wide field 3D deconvolution
  • AutoDeblur, AutoVisualize, Object counting and Tracking, FRET/Ratiometrics, Colocalization and Image Alignment
  • Other useful off-line software: Image J, Adobe Photoshop  

top of page

Contact
Jyothi Arikkath, PhD
Assistant Professor
Developmental Neuroscience
Munroe-Meyer Institute
Durham Research Center II, Room 3031
University of Nebraska Medical Center
985960 Nebraska Medical Center
Omaha, NE 68198-5960
402 559 8461 (office)
402 559 8462 (lab)
jyothi.arikkath@unmc.edu

Training Information/User Tips

;